Connecting the Coil Cable Junction Box to the Mount Base

  1. If you are replacing the coil cable, remove the coil cable from the shaft cap (Removing the Coil Cable from the Shaft Cap).
  2. If necessary, install the replacement coil cable in the shaft cap (Installing the Coil Cable in the Shaft Cap).
  3. Route the power cable and transducer cable (if present) through the mount base (Routing the Power and Transducer Cables Through the Mount).
  4. Align the coil cable junction box with the holes on the mount base.
  5. Using a 3mm hex bit or screwdriver, insert and tighten the three screws Callout number 1 to secure the coil cable junction box to the mount base.


  6. Apply dielectric grease to the data cable connector Callout number 2, and ensure the o-ring is in place.
  7. Reconnect the data cable.
GUID-828BF524-69C7-4E20-A109-CE89908F9BDD v2