Removing the Nose Cone and Transducer

Before you can remove the nose cone and transducer, you must remove the propeller drive motor (Removing the Propeller Drive Motor).

  1. Carefully pull the transducer cable Callout number one straight down through the bottom of the shaft until it is completely removed from the shaft.

    View of transducer wire removal with callout
  2. After you pull the transducer cable out of the shaft, pull it through the hole in the front of the shaft base Callout number two, along with the rubber cable gland and the recessed nut.

  3. Dispose of the cable gland and recessed nut.

    The shaft and motor hardware service kit contains a new cable gland and recessed nut.

Copyright © Garmin. All rights reserved.GUID-F61CDD86-17CE-4801-B775-07A31282A541 v2