Premature Descent Alerting

A Premature Descent Alert (PDA) occurs when the system detects the aircraft is significantly below the normal approach path to a runway.

PDA alerting begins when the aircraft is below 500 feet AGL within 15 NM of the destination airport and ends when the aircraft is 0.5 NM from the runway threshold.

255: PDA Alerting Threshold