Installing the Transmitter on a High Pressure Hose Extension
Always use the pre-installed flow restrictor when using the transmitter directly attached to your regulator (Installing the Transmitter on Your Tank Regulator). Always use the included air spool when connecting the transmitter to a high pressure hose extension. Using the transmitter without either the flow restrictor or air spool could result in serious injury or death from an air pressurization failure.
Inspect all o-rings before installing the transmitter, flow restrictor, or air spool, and verify they are clean and undamaged. Replace worn or damaged o-rings as needed.
Before you install the transmitter on a high pressure hose extension certified to the EN 250:2014 standard, you should read the transmitter position tips and choose a position that provides the best line of sight to the dive computer.
To install the transmitter, you need two 5/8 in. (16 mm) open-ended wrenches and a small flat screwdriver or flat-nose pliers.
The transmitter can connect to a high pressure hose extension from the high pressure output port of the first-stage regulator.
You must remove the air spool and reinstall the flow restrictor before installing the transmitter on your tank regulator.