Dive Alerts

Alert Message

Cause

Watch Action

None

You completed the decompression stop.

The decompression stop depth and time flash for five seconds.

None

Your partial pressure of oxygen (PO2) value is above the specified warning value.

Your PO2 value flashes.

%1 OTU accumulated. End your dive now.

Your oxygen toxicity units are above the safe limit. During a dive, "%1" is replaced with the number of units accumulated.

The alert appears every two minutes, up to three times.

250 OTU accumulated.

Your oxygen toxicity units (OTU) are at 250 units, and you are nearing the safe limit of 300 units.

None

Approaching Deco Stop

You are within one stop interval (3 m or 9.8 ft.) of the decompression stop depth.

None

Approaching NDL

You have 10 minutes of no decompression limit (NDL) time remaining.

The alert appears again when you have 5 minutes of NDL time remaining.

Ascending too fast. Slow your ascent.

You are ascending faster than 9.1 m/min. (30 ft./min.) for more than 5 seconds.

None

Battery critically low. End your dive now.

Less than 10% battery power remains.

The alert appears when the watch is below 10% battery power and on the dive pre-check screen for your next dive.

Battery is low.

Less than 20% battery power remains.

The alert appears when the watch is below 20% battery power and on the dive pre-check screen for your next dive.

Continuing on %1. Switch at any time.

You selected Not Now when prompted to switch to a higher-oxygen gas, or you ignored the prompt.

The watch marks the gas as a backup and updates decompression guidance accordingly.

CNS toxicity at %1%. End your dive now.

Your CNS oxygen toxicity is too high. During a dive, "%1" is replaced with your current CNS percentage.

The alert appears every two minutes, up to three times.

CNS toxicity at 80%.

Your central nervous system (CNS) oxygen toxicity is at 80% of the safe limit.

The alert appears during a dive and on the dive pre-check screen for your next dive.

Decompression Cleared

You completed all decompression stops.

None

Descend below deco ceiling.

You are more than 0.6 m (2 ft.) above the decompression ceiling.

The current depth and stop depth flash.

If you remain above the decompression ceiling for more than three minutes, the decompression lockout feature goes into effect.

Descend to complete safety stop.

You are more than 2 m (8 ft.) above the safety stop ceiling.

The current depth and stop depth flash.

Diluent PO2 is low. Flushing may be dangerous.

The PO2 of the diluent gas is too low, and filling the rebreather breathing loop with the diluent gas may be dangerous.

None

Dive will end in %1 seconds.

The watch will automatically end and save the dive. During a dive, "%1" is replaced by the number of seconds.

None

Do not dive. Failed to read depth sensor.

The watch has invalid or missing depth sensor data before you start a dive activity.

Do not start a dive. Call Garmin® Product Support.

Failed to read depth sensor. End your dive now.

The watch has invalid or missing depth sensor data after you have started a dive activity.

Use a backup dive computer or dive plan and end your dive. Call Garmin Product Support.

NDL exceeded. Decompression now required.

You have exceeded your NDL time.

The watch begins providing decompression stop guidance.

No more gas switch alerts will be issued.

You selected Never when prompted to switch to a higher-oxygen gas.

The watch marks the gas as a backup and updates decompression guidance accordingly. It will no longer prompt you to switch to the gas.

PO2 is high. Ascend or switch to lower O2 gas.

Your PO2 value is above the specified critical value.

Your PO2 value flashes.

The alert appears every 30 seconds, up to three times, until you ascend to a safe level or switch gases.

PO2 is low. Descend or switch to higher O2 gas.

Your PO2 value is below 0.18 bar.

Your PO2 value flashes.

The alert appears every 30 seconds, up to three times, until you descend to a safe level or switch gases.

Safety Stop Cleared

You completed the safety stop.

None

Safety Stop Started

You ascended above 6 m (20 ft.) without other decompression guidance.

The safety stop countdown timer begins, if configured.

Switch to %1 now?

In a multi-gas dive, a gas with a higher oxygen content is now safe to breathe. During a dive, "%1" is replaced with the name of the gas.

You can switch gases now, or wait to switch gases later in the dive. A confirmation message for your choice appears.

Switched to high setpoint.

The watch automatically switched to your specified CCR high setpoint.

None

Switched to low setpoint.

The watch automatically switched to your specified CCR low setpoint.

None

This pool dive will not be saved to the dive log.

The watch is in pool dive mode.

The watch will not save the current dive to the dive log.

Watch rebooted. Evaluate dive conditions.

The watch rebooted during the dive.

The watch simulates the dive for the time it was rebooting. Since other alerts may not have been triggered, evaluate your current depth and dive conditions.

GUID-2A58ED2A-14A3-4161-ADB5-259E1781AF1B v7
July 2024