Opening the Pedestal Housing

WARNING

The high voltage capacitors in this product can hold a charge well after disconnecting power. While servicing the unit, take all necessary precautions against high voltage. High voltage electrocution can result in serious personal injury or death.

  1. Using a 6 mm hex wrench, remove the four screws that secure the housing cover to the pedestal housing.
  2. Pry the cover away from the housing.
    NOTICE

    If necessary, you should use a non-marring plastic pry tool to prevent scratching the device. Scratching the device may lead to premature corrosion of the housing.

  3. Slide the cover away from the housing and set it aside.

Before proceeding with service, you should familiarize yourself with the internal components of the radar (Overview).