Lamp and Horn Connections

The device can be used with a lamp, a horn, or both, to sound or flash an alert when the chartplotter displays a message. This is optional, and the alarm wire is not necessary for the device to function normally. When connecting the device to a lamp or horn, observe these considerations.

  • The alarm circuit switches to a low-voltage state when the alarm sounds.

  • The maximum current is 100 mA, and a relay is needed to limit the current from the chartplotter to 100 mA.

  • To manually toggle visual and audible alerts, you can install single-pole, single-throw switches.


Wiring diagram with callouts

Item

Description

Callout number 1

Power source

Callout number 2

Power cable

Callout number 3

Horn

Callout number 4

Lamp

Callout number 5

Relay (100 mA coil current)

Callout number 6

Toggle switches to enable and disable lamp or horn alerts

Item

Wire Color

Wire Function

Callout number 1

Red

Power

Callout number 2

Black

Ground

Callout number 3

Yellow

Alarm

GUID-BF2FF273-008A-482A-A96F-362ADA8996BA v6