Replacing the Internal Network Cable

  1. Carefully cut the cable tie securing the internal power and network cables to the bottom cover.
  2. Using a flat screwdriver or prying tool, lift the retaining latch on the under side of the internal network connector and disconnect it from the electronics box.
    NOTE: The internal network cable connector is a standard water-resistant RJ45 connector.
  3. Using a 16 mm (5/8 in.) socket wrench, remove the nut that secures the connector on the outside of the pedestal housing.
  4. Remove the cable.
  5. Examine the O-ring on the threaded end of the new internal network cable and make sure it is fully seated into its groove.
  6. Feed the threaded end of the cable through its slot, and install the locking nut.
  7. Connect the cable to the electronics box.
  8. Secure the internal power and network cables to the bottom cover with a new cable tie.
    NOTE: The cable tie helps to prevent the internal cables working themselves loose over time.
GUID-88552399-6550-4627-8663-5DCEC42854AD v1
November 2025