Calibrating the Fuel Flow:
-
On the MFW:
- With the "Engine" Page selected on the MFW, press the MENU Softkey (on the MFW side of the PFD while in split screen mode) to open the 'EIS Menu' Window.
- Touch the Fuel Flow Calibration Button.
-
The Actual Qty
Used Selection Button is used when the known
amount of fuel has been calculated.
- Touch the Actual Qty Used Selection Button and enter an amount on the numeric keypad that opens.
- Touch the Enter Button to accept the actual amount of fuel used.
-
The Adjustment
Selection Button is used when the difference
of fuel flow is known.
- Touch the Adjustment Selection Button and enter a percentage that represents the difference in fuel flow (between -10.0 and +10.0 percent).
- Touch the Enter Button to accept the percentage of fuel flow difference.
When entering a fuel flow adjustment percentage the Fuel Used Datafield Button will adjust accordingly to the updated fuel flow.
Parent Topic: Fuel Flow Calibration