Power Cable Extensions

If necessary, the power cable can be extended using the appropriate wire gauge for the length of the extension.
Power cable with an extension, with callouts

Callout number 1

Splice

Callout number 2

  • Up to 4.6 m (15 ft.): 10 AWG (5.26 mm2) extension wire

  • Up to 7 m (23 ft.): 8 AWG (8.36 mm2) extension wire

  • Up to 11 m (36 ft.): 6 AWG (13.29 mm2) extension wire

Callout number 3

Fuse (10 A, 42 V fast-acting)

Callout number 4

20.3 cm (8 in.)

Callout number 5

Battery

Callout number 6

20.3 cm (8 in.)

Callout number 7

11 m (36 ft.) maximum extension

GUID-16AB9F2E-6D52-48FF-BCCC-C0633F54CC95 v2
August 2024