Dive Alerts
|
Alert Message |
Cause |
Dive Computer Action |
|---|---|---|
|
None |
You completed the decompression stop. |
The decompression stop depth and time flash. |
|
None |
Your partial pressure of oxygen (PO2) value is above the specified warning value. |
Your PO2 value flashes yellow. |
|
%1 OTU accumulated. |
Your oxygen toxicity units are above the safe limit. During a dive, “%1” is replaced with the number of units accumulated. |
The alert appears every two minutes, up to three times. |
|
250 OTU accumulated. |
Your oxygen toxicity units (OTU) are at 250 units, and you are nearing the safe limit of 300 units. |
None |
|
5 minutes to NDL. |
You have 5 minutes of no decompression limit (NDL) time remaining. |
None |
|
10 minutes to NDL. |
You have 10 minutes of no decompression limit (NDL) time remaining. |
None |
|
Approaching deco stop. |
You are within one stop interval (3 m or 9.8 ft.) of the decompression stop depth. |
None |
|
ASCEND OR SWITCH GAS PO2 is high. |
Your PO2 value is above the specified critical value. |
Your PO2 value flashes red. The alert appears every 30 seconds, up to three times, until you ascend to a safe level. |
|
Battery is low. |
Less than 20% battery power remains. |
The alert appears when the dive computer is below 20% battery power. |
|
Continuing on %1. Switch at any time. |
You selected Not Now when prompted to switch to a higher-oxygen gas, or you ignored the prompt. |
The gas does not change. You will be prompted again in two minutes. |
|
CNS toxicity at 80%. |
Your central nervous system (CNS) oxygen toxicity is at 80% of the safe limit. |
The alert appears during a dive and on the dive pre-check screen for your next dive. |
|
CNS toxicity at %1%. |
Your CNS oxygen toxicity is too high. During a dive, “%1” is replaced with your current CNS percentage. |
The alert appears every two minutes, up to three times. |
|
Decompression cleared. |
You completed all decompression stops. |
None |
|
DESCEND OR SWITCH GAS |
Your PO2 value is below 0.18 bar. |
If you are within the first two minutes of your dive, your PO2 value flashes yellow. |
|
DESCEND TO %1 |
You are more than 0.6 m (2 ft.) above the decompression ceiling. During a dive, “%1” is replaced with the depth you should descend to. |
The current depth and stop depth flash red. If you remain above the decompression ceiling for more than three minutes, the decompression lockout feature goes into effect. |
|
Descend to complete safety stop. |
You are more than 2 m (8 ft.) above the safety stop ceiling. |
The current depth and stop depth turn yellow. |
|
Dive will end in %1 seconds. |
The dive computer will automatically end and save the dive. During a dive, “%1” is replaced by the number of seconds. |
None |
|
Do not dive. Failed to read depth sensor. |
The dive computer has invalid or missing depth sensor data before you start a dive activity. |
Do not start a dive. Call Garmin Product Support. |
|
EVALUATE DIVE CONDITIONS |
The dive computer rebooted during the dive. |
The dive computer simulates the dive for the time it was rebooting. Since other alerts may not have been triggered, evaluate your current depth and dive conditions. |
|
NDL exceeded. Deco required. |
You have exceeded your NDL time. |
The dive computer begins providing decompression stop guidance. |
|
SAFELY END DIVE Battery critically low. |
Less than 10% battery power remains. |
The alert appears when the dive computer is below 10% battery power. |
|
SAFELY END DIVE Dive computer error. |
The computer encountered an issue that it could not recover from. |
Use a backup dive computer or dive plan and end your dive. Residual tissue loading was cleared. If the issue continues, call Garmin Product Support. |
|
SAFELY END DIVE Failed to read depth sensor. |
The dive computer has invalid or missing depth sensor data after you have started a dive activity. |
Use a backup dive computer or dive plan and end your dive. Call Garmin Product Support. |
|
Safety stop cleared. |
You completed the safety stop. |
None |
|
Safety stop started. |
You ascended above 6 m (20 ft.) without other decompression guidance. |
The safety stop countdown timer begins, if configured. |
|
SLOW YOUR ASCENT Ascending too fast. |
You are ascending faster than 9.1 m/min. (30 ft./min.) for more than 5 seconds. |
None |
|
Switch to %1 now? |
In a multi-gas dive, a gas with a higher oxygen content is now safe to breathe. |
You can switch gases now, or wait to switch gases later in the dive. A confirmation message for your choice appears. |
|
This pool dive will not be saved to the dive log. |
The dive computer is in pool dive mode. |
The dive computer will not save the current dive to the dive log. |